Follow
Norhayati Mahyuddin
Norhayati Mahyuddin
Associate Professor Dr. Sr
Verified email at um.edu.my
Title
Cited by
Cited by
Year
Thermal conductivity of concrete–A review
I Asadi, P Shafigh, ZFBA Hassan, NB Mahyuddin
Journal of Building Engineering 20, 81-93, 2018
5702018
A review on natural ventilation applications through building façade components and ventilation openings in tropical climates
A Aflaki, N Mahyuddin, ZAC Mahmoud, MR Baharum
Energy and buildings 101, 153-162, 2015
3152015
Thermal performance of atria: An overview of natural ventilation effective designs
L Moosavi, N Mahyuddin, N Ab Ghafar, MA Ismail
Renewable and Sustainable Energy Reviews 34, 654-670, 2014
2272014
Concrete as a thermal mass material for building applications-A review
P Shafigh, I Asadi, NB Mahyuddin
Journal of Building Engineering 19, 14-25, 2018
1332018
A Review of CO2 Measurement Procedures in Ventilation Research
N Mahyuddin, H Awbi
International Journal of Ventilation 10 (4), 353-370, 2012
1142012
The spatial distribution of carbon dioxide in an environmental test chamber
N Mahyuddin, H Awbi
Building and Environment 45 (9), 1993-2001, 2010
852010
Recycling of end-of-life vehicles (ELVs) for building products: Concept of processing framework from automotive to construction industries in Malaysia
YC Wong, KM Al-Obaidi, N Mahyuddin
Journal of Cleaner Production 190, 285-302, 2018
822018
A review on indoor environmental quality (IEQ) and energy consumption in building based on occupant behavior
I Asadi, N Mahyuddin, P Shafigh
Facilities 35 (11/12), 684-695, 2017
762017
Atrium cooling performance in a low energy office building in the Tropics, a field study
L Moosavi, N Mahyuddin, N Ghafar
Building and Environment 94, 384-394, 2015
642015
Thermal properties of cement mortar with different mix proportions
P Shafigh, I Asadi, AR Akhiani, NB Mahyuddin, M Hashemi
Materiales de Construcción 70 (339), e224-e224, 2020
612020
The influence of single-sided ventilation towards the indoor thermal performance of high-rise residential building: A field study
A Aflaki, N Mahyuddin, MR Baharum
Energy and Buildings 126, 146-158, 2016
572016
Malaysia’s rising GHG emissions and carbon ‘lock-in’risk: A review of Malaysian building sector legislation and policy
SM Zaid, NE Myeda, N Mahyuddin, R Sulaiman
Journal of Surveying, Construction and Property 6 (1), 1-13, 2015
542015
Improving the air change rate in high-rise buildings through a transom ventilation panel: A case study
A Aflaki, K Hirbodi, N Mahyuddin, M Yaghoubi, M Esfandiari
Building and Environment 147, 35-49, 2019
452019
The spatial distribution of carbon dioxide in rooms with particular application to classrooms
N Mahyuddin, HB Awbi, M Alshitawi
Indoor and Built Environment 23 (3), 433-448, 2014
422014
Lack of energy efficiency legislation in the malaysian building sector contributes to Malaysia’s growing GHG emissions
SM Zaid, NE Myeda, N Mahyuddin, R Sulaiman
E3S Web of Conferences 3, 01029, 2014
342014
Thermophysical properties of sustainable cement mortar containing oil palm boiler clinker (OPBC) as a fine aggregate
I Asadi, P Shafigh, M Hashemi, AR Akhiani, M Maghfouri, B Sajadi, ...
Construction and Building Materials 268, 121091, 2021
312021
Building height effects on indoor air temperature and velocity in high rise residential buildings in tropical climate
A Aflaki, N Mahyuddin, G Manteghi, M Baharum
OIDA International Journal of Sustainable Development 7 (07), 39-48, 2014
312014
Rethinking construction safety: An introduction to total safety management
A Suraji, K Sulaiman, N Mahyuddin, O Mohamed
Journal of construction research 7 (01n02), 49-63, 2006
302006
Computational fluid dynamics modelling of the air movement in an environmental test chamber with a respiring manikin
N Mahyuddin, HB Awbi, EA Essah
Journal of Building Performance Simulation 8 (5), 359-374, 2015
272015
Sick building symptoms among children in private pre-schools in Malaysia: Association of different ventilation strategies
NM Salleh, SN Kamaruzzaman, N Mahyuddin
Journal of Building Performance 4 (1), 2013
262013
The system can't perform the operation now. Try again later.
Articles 1–20