CFD analysis of cross-ventilation of a generic isolated building with asymmetric opening positions: Impact of roof angle and opening location JI Perén, T Van Hooff, BCC Leite, B Blocken Building and Environment 85, 263-276, 2015 | 238 | 2015 |
Impact of roof geometry of an isolated leeward sawtooth roof building on cross-ventilation: Straight, concave, hybrid or convex? JI Peren, T Van Hooff, R Ramponi, B Blocken, BCC Leite Journal of Wind Engineering and Industrial Aerodynamics 145, 102-114, 2015 | 77 | 2015 |
CFD simulation of wind-driven upward cross ventilation and its enhancement in long buildings: Impact of single-span versus double-span leeward sawtooth roof and opening ratio JI Perén, T Van Hooff, BCC Leite, B Blocken Building and Environment 96, 142-156, 2016 | 76 | 2016 |
Impact of eaves on cross-ventilation of a generic isolated leeward sawtooth roof building: Windward eaves, leeward eaves and eaves inclination JI Perén, T Van Hooff, BCC Leite, B Blocken Building and Environment 92, 578-590, 2015 | 66 | 2015 |
Analysis of thermal comfort in an office environment with underfloor air supply in a tropical climate BCC Leite, A Tribess HVAC&R Research 12 (2), 215-229, 2006 | 32 | 2006 |
Sistema de ar condicionado com insuflamento pelo piso em ambientes de escritórios: avaliação do conforto térmico e condições de operação. BCC Leite Universidade de São Paulo, 2003 | 30 | 2003 |
Analysis of the underfloor air distribution system: Thermal comfort and energy consumption BCC Leite, A Tribess Room Vent 2002: proceedings, 2002 | 27 | 2002 |
Performance of aerogel as a thermal insulation material towards a sustainable design of residential buildings for tropical climates in Nigeria AW Bashir, BCC Leite Energy and Built Environment 3 (3), 291-315, 2022 | 19 | 2022 |
Assessing Brazilian workplace performance SW Ornstein, CM de Andrade, BCC Leite Assessing building performance, 128-139, 2006 | 16 | 2006 |
Decision-making process for thermal comfort and energy efficiency optimization coupling smart-window and natural ventilation in the warm and hot climates EH Suzuki, FC Lofrano, FA Kurokawa, RTA Prado, BCC Leite Energy and Buildings 266, 112110, 2022 | 14 | 2022 |
Energy consumption of Underfloor Air Distribution Systems: a literature overview TAH Inatomi, V Abe, BCC Leite The 23th Conference on Passive and Low Energy Architecture, 2006 | 11 | 2006 |
Avaliação do desempenho térmico de fachada com painéis leves em edificações de múltiplos pavimentos AC ROCHA, M Barros, BCC LEITE, JRD PETRECHE Encontro Nacional de Tecnologia do Ambiente Construído–ENTAC, São Paulo, Brasil, 2016 | 9 | 2016 |
Individually controlled office environments. Thermal comfort parameters determination BCC Leite, A Tribess | 9 | 2004 |
Análise do desempenho de edifícios de escritórios automatizados através da avaliação pós-ocupação BCC Leite, SW Ornstein | 8 | 1997 |
Amendoim no telhado: O comportamento da grama-amendoim (Arachis repens) na cobertura verde extensiva IL Ferraz, BCC Leite Anais: ELECS 2011 VITORIAES, 2011 | 7 | 2011 |
Soluções baseadas na natureza: quadro da ocupação da cidade de São Paulo por células de biorretenção MCS Pereira, L Gobatti, MC Soares, BCC Leite, JRS Martins Revista LABVERDE 11 (1), 95-120, 2021 | 6 | 2021 |
Da geometria cotada ao modelamento 3D: projeto didático ET Santos, R Mafalda, A Kawano, LY Cheng, JRD Petreche, BCC Leite, ... Simpósio Nacional de Geometria Descritiva e Desenho Técnico e International …, 2003 | 6 | 2003 |
Avaliação pós-ocupação (APO) aplicada em edifício antigo requalificado para abrigar centro de teleatendimento 24 horas CM Andrade, BCC Leite, SW Ornstein, CG Maleronka Anais do ENTAC 2002-Livros de resumos: cooperação & responsabilidade social, 2002 | 5 | 2002 |
Conforto térmico em ambientes de escritórios com distribuição de ar pelo piso BCC Leite, A Tribess CONBRAVA, 2001 | 5 | 2001 |
Office Workplaces in São Paulo, Brazil: Some Buildings Performance Considerations.“ SW Ornstein, C ANDRADE, BCC Leite Proceedings of the 30th Annual Conference of the Environmental Design …, 1999 | 5 | 1999 |