Seguir
Jeison Fonseca
Jeison Fonseca
Engenheiro Eletrônico, Instituto Dante Pazzanese de Cardiologia
E-mail confirmado em dantepazzanese.org.br
Título
Citado por
Citado por
Ano
New centrifugal blood pump with dual impeller and double pivot bearing system: wear evaluation in bearing system, performance tests, and preliminary hemolysis tests
E Bock, A Ribeiro, M Silva, P Antunes, J Fonseca, D Legendre, J Leme, ...
Artificial Organs 32 (4), 329-333, 2008
762008
Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases
D Legendre, J Fonseca, A Andrade, JF Biscegli, R Manrique, D Guerrino, ...
Artificial organs 32 (6), 461-467, 2008
542008
Cardiovascular simulator improvement: pressure versus volume loop assessment
J Fonseca, A Andrade, DEC Nicolosi, JF Biscegli, J Leme, D Legendre, ...
Artificial Organs 35 (5), 454-458, 2011
402011
Implantable centrifugal blood pump with dual impeller and double pivot bearing system: electromechanical actuator, prototyping, and anatomical studies
E Bock, P Antunes, T Leao, B Uebelhart, J Fonseca, J Leme, B Utiyama, ...
Artificial Organs 35 (5), 437-442, 2011
392011
A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests
J Leme, J Fonseca, E Bock, C da Silva, BU da Silva, AE Dos Santos, ...
Artificial Organs 35 (5), 443-447, 2011
292011
Study of a centrifugal blood pump in a mock loop system
B Uebelhart, BU da Silva, J Fonseca, E Bock, J Leme, C da Silva, T Leão, ...
Artificial organs 37 (11), 946-949, 2013
252013
A new technique to control brushless motor for blood pump application
J Fonseca, A Andrade, DEC Nicolosi, JF Biscegli, D Legendre, E Bock, ...
Artificial organs 32 (4), 355-359, 2008
232008
Specification of supervisory control systems for ventricular assist devices
ACM Cavalheiro, DJ Santos Fo, A Andrade, JR Cardoso, O Horikawa, ...
Artificial Organs 35 (5), 465-470, 2011
212011
In vitro evaluation of multi‐objective physiological control of the centrifugal blood pump
T Leao, B Utiyama, J Fonseca, E Bock, A Andrade
Artificial organs 44 (8), 785-796, 2020
202020
An electro‐fluid‐dynamic simulator for the cardiovascular system
CL Felipini, AJP De Andrade, JC Lucchi, JWG Da Fonseca, D Nicolosi
Artificial Organs 32 (4), 349-354, 2008
202008
Introductory tests to in vivo evaluation: Magnetic coupling influence in motor controller
E Bock, A Andrade, J Dinkhuysen, C Arruda, J Fonseca, J Leme, ...
ASAIO Journal 57 (5), 462-465, 2011
152011
Endurance test on a textured diaphragm for the auxiliary total artificial heart (ATAH)
D Legendre, OL Da Silva, A Andrade, J Fonseca, D Nicolosi, J Biscegli
Artificial organs 27 (5), 457-460, 2003
152003
In Vitro Assessment of the A pico A ortic B lood P ump: Anatomical Positioning, Hydrodynamic Performance, Hemolysis Studies, and Analysis in a Hybrid Cardiovascular Simulator
BU da Silva, AD Jatene, J Leme, JWG Fonseca, C Silva, B Uebelhart, ...
Artificial Organs 37 (11), 950-953, 2013
142013
Speed control of the implantable centrifugal blood pump to avoid aortic valve stenosis: Simulation and implementation
T Leão, J Fonseca, E Bock, R Sá, B Utiyama, E Drigo, J Leme, A Andrade
5th IEEE RAS/EMBS International Conference on Biomedical Robotics and …, 2014
132014
Design of supervisory control system for ventricular assist device
A Cavalheiro, D Santos Fo, A Andrade, JR Cardoso, E Bock, J Fonseca, ...
Technological Innovation for Sustainability: Second IFIP WG 5.5/SOCOLNET …, 2011
122011
Estudo de comportamento de fluxo através de modelo físico e computacional de aneurisma de aorta infra-renal obtido por tomografia.
DF Legendre
Universidade de São Paulo, 2009
122009
Educational Data Mining: A Literature Review; Europe and MENA Cooperation Advances in Information and Communication Technologies
C Silva, J Fonseca
Springer: Cham, Switzerland, 2017
10*2017
Improvement on the auxiliary total artificial heart (ATAH) left chamber design
A Andrade, J Fonseca, D Legendre, D Nicolosi, J Biscegli, M Pinotti, ...
Artificial organs 27 (5), 452-456, 2003
102003
Left ventricle failure and blood flow estimation for centrifugal blood pumps
EGP Bock, T Leão, J Fonseca, A Andrade
Automation, 162, 2015
92015
Construção de biomodelos por impressão 3D para uso na prática clínica: experiência do instituto dante pazzanese de cardiologia
B Utiyama, C Hernandes, T Senra, M Gospos, R Sá, J Leme, J Fonseca, ...
Anais do XXIV Congresso Brasileiro de Engenharia Biomédica, 316-9, 2014
92014
O sistema não pode executar a operação agora. Tente novamente mais tarde.
Artigos 1–20