Follow
Guangyu Cao
Guangyu Cao
Professor of Energy and Indoor Climate, Norwegian University of Science and Technology
Verified email at ntnu.no - Homepage
Title
Cited by
Cited by
Year
A review of the performance of different ventilation and airflow distribution systems in buildings
G Cao, H Awbi, R Yao, Y Fan, K Sirén, R Kosonen, JJ Zhang
Building and Environment 73, 171-186, 2014
5012014
Protected zone ventilation and reduced personal exposure to airborne cross‐infection
G Cao, PV Nielsen, RL Jensen, P Heiselberg, L Liu, J Heikkinen
Indoor air 25 (3), 307-319, 2015
832015
Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow?
G Cao, MCA Storås, A Aganovic, LI Stenstad, JG Skogås
American journal of infection control 46 (10), 1115-1122, 2018
612018
Modelling and experimental study of performance of the protected occupied zone ventilation
G Cao, K Sirén, S Kilpeläinen
Energy and Buildings 68, 515-531, 2014
612014
Particle Image Velocimetry (PIV) application in the measurement of indoor air distribution by an active chilled beam
G Cao, M Sivukari, J Kurnitski, M Ruponen, O Seppänen
Building and Environment 45 (9), 1932-1940, 2010
602010
Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system
A Aganovic, G Cao, LI Stenstad, JG Skogås
Building and Environment 126, 42-53, 2017
532017
Simulation of the heating performance of the Kang system in one Chinese detached house using biomass
G Cao, J Jokisalo, G Feng, L Duanmu, M Vuolle, J Kurnitski
Energy and Buildings 43 (1), 189-199, 2011
512011
Modelling and simulation of the near-wall velocity of a turbulent ceiling attached plane jet after its impingement with the corner
G Cao, M Ruponen, R Paavilainen, J Kurnitski
Building and Environment 46 (2), 489-500, 2011
482011
Laminar airflow and mixing ventilation: Which is better for operating room airflow distribution near an orthopedic surgical patient?
G Cao, AM Nilssen, Z Cheng, LI Stenstad, A Radtke, JG Skogås
American journal of infection control 47 (7), 737-743, 2019
462019
PIV measurement of the attached plane jet velocity field at a high turbulence intensity level in a room
G Cao, M Sivukari, J Kurnitski, M Ruponen
International Journal of Heat and Fluid Flow 31 (5), 897-908, 2010
372010
Experimental investigation of the velocity distribution of the attached plane jet after impingement with the corner in a high room
G Cao, M Ruponen, J Kurnitski
Energy and Buildings 42 (6), 935-944, 2010
332010
Identifying key design parameters of the integrated energy system for a residential Zero Emission Building in Norway
N Nord, LH Qvistgaard, G Cao
Renewable Energy 87, 1076-1087, 2016
322016
Experimental investigation and modelling of a buoyant attached plane jet in a room
G Cao, J Kurnitski, M Ruponen, O Seppänen
Applied thermal engineering 29 (14-15), 2790-2798, 2009
322009
Experimental study of the effect of turbulence intensities on the maximum velocity decay of an attached plane jet
G Cao, C Kandzia, D Müller, J Heikkinen, R Kosonen, M Ruponen
Energy and Buildings 65, 127-136, 2013
302013
Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system
A Aganovic, G Cao
Indoor and Built Environment 28 (8), 1092-1103, 2019
282019
Characterizing the Dynamic Interactions and Exposure Implications of a Particle-Laden Cough Jet with Different Room Airflow Regimes Produced by Low and High Momentum Jets
G Cao, S Liu, BE Boor, A Novoselac
Aerosol and Air Quality Research 15 (5), 1955-1966, 2015
232015
Active chilled beam wall jet prediction by the free convection model
G Cao, J Kurnitski, P Mustakallio, O Seppänen
International Journal of Ventilation 7 (2), 169-178, 2008
212008
Plane-air-jet corner zone modelling in a room ventilated by an active chilled beam
G Cao, J Kurnitski, M Ruponen, P Mustakallio, O Seppänen
International Journal of Ventilation 7 (4), 287-297, 2009
192009
Energy cost models for air supported sports hall in cold climates considering energy efficiency
N Nord, HM Mathisen, G Cao
Renewable Energy 84, 56-64, 2015
172015
Dynamic interaction of a downward plane jet and a cough jet with respect to particle transmission: An analytical and experimental study
G Cao, S Liu, BE Boor, A Novoselac
Journal of occupational and environmental hygiene 14 (8), 618-631, 2017
162017
The system can't perform the operation now. Try again later.
Articles 1–20