Nitric oxide monitoring in brain extracellular fluid: characterisation of Nafion®-modified Pt electrodes in vitro and in vivo
FO Brown, NJ Finnerty, JP Lowry
Analyst 134 (10), 2012-2020, 2009
602009
Calibration of NO sensors for in-vivo voltammetry: laboratory synthesis of NO and the use of UV–visible spectroscopy for determining stock concentrations
FO Brown, NJ Finnerty, FB Bolger, J Millar, JP Lowry
Analytical and bioanalytical chemistry 381, 964-971, 2005
522005
Prefrontal GABAB receptor activation attenuates phencyclidine-induced impairments of prepulse inhibition: involvement of nitric oxide
K Fejgin, E Pålsson, C Wass, N Finnerty, J Lowry, D Klamer
Neuropsychopharmacology 34 (7), 1673-1684, 2009
382009
Brain nitric oxide: Regional characterisation of a real-time microelectrochemical sensor
NJ Finnerty, SL O’Riordan, E Palsson, JP Lowry
Journal of neuroscience methods 209 (1), 13-21, 2012
352012
An investigation of hypofrontality in an animal model of schizophrenia using real-time microelectrochemical sensors for glucose, oxygen, and nitric oxide
NJ Finnerty, FB Bolger, E Pålsson, JP Lowry
ACS Chemical Neuroscience 4 (5), 825-831, 2013
302013
In vivo characterisation of a Nafion®-modified Pt electrode for real-time nitric oxide monitoring in brain extracellular fluid
NJ Finnerty, SL O'Riordan, FO Brown, PA Serra, RD O'Neill, JP Lowry
Analytical methods 4 (2), 550-557, 2012
292012
Increased brain nitric oxide levels following ethanol administration
N Finnerty, SL O'Riordan, D Klamer, J Lowry, E Pålsson
Nitric Oxide 47, 52-57, 2015
282015
Increased cortical nitric oxide release after phencyclidine administration
E Pålsson, N Finnerty, K Fejgin, D Klamer, C Wass, L Svensson, J Lowry
Synapse 63 (12), 1083-1088, 2009
282009
In vitro characterisation of ortho phenylenediamine and NafionŪ-modified Pt electrodes for measuring brain nitric oxide
AM Wynne, CH Reid, NJ Finnerty
Journal of Electroanalytical Chemistry 732, 110-116, 2014
242014
Continuous real-time in vivo measurement of cerebral nitric oxide supports theoretical predictions of an irreversible switching in cerebral ROS after sufficient exposure to …
NJ Finnerty, SL O'Riordan, JP Lowry, M Cloutier, P Wellstead
Journal of Parkinson's disease 3 (3), 351-362, 2013
132013
Physiological monitoring of tissue pH: in vitro characterisation and in vivo validation of a quinone-modified carbon paste electrode
KM Herdman, CB Breslin, NJ Finnerty
Electrochimica Acta 298, 484-495, 2019
102019
In vitro development and in vivo application of a platinum-based electrochemical device for continuous measurements of peripheral tissue oxygen
NJ Finnerty, FB Bolger
Bioelectrochemistry 119, 124-135, 2018
102018
Long term amperometric recordings in the brain extracellular fluid of freely moving immunocompromised NOD SCID mice
CH Reid, NJ Finnerty
Sensors 17 (2), 419, 2017
92017
A platinum oxide-based microvoltammetric pH electrode suitable for physiological investigations
NJ Finnerty, FB Bolger
Analyst 143 (13), 3124-3133, 2018
82018
In–Vitro Development and Characterisation of a Superoxide Dismutase‐Based Biosensor.
MM Doran, NJ Finnerty, JP Lowry
ChemistrySelect 2 (14), 4157-4164, 2017
82017
Electrochemical sensors: in-vitro and in-vivo analysis of brain nitric oxide and regional cerebral blood flow
NJ Finnerty
National University of Ireland, Maynooth, 2008
72008
An electrochemical investigation into the effects of local and systemic administrations of sodium nitroprusside in brain extracellular fluid of mice
CH Reid, NJ Finnerty
Bioelectrochemistry 132, 107441, 2020
62020
Real-Time Amperometric Recording of Extracellular H2O2 in the Brain of Immunocompromised Mice: An In Vitro, Ex Vivo and In Vivo Characterisation Study
CH Reid, NJ Finnerty
Sensors 17 (7), 1596, 2017
62017
Ascorbic acid rejection characteristics of modified platinum electrodes: a shelf life investigation
AM Wynne, NJ Finnerty
Chemosensors 3 (2), 55-69, 2015
62015
The aqueous deposition of a pH sensitive quinone on carbon paste electrodes using linear sweep voltammetry
KM Herdman, CB Breslin, NJ Finnerty
Journal of Electroanalytical Chemistry 828, 137-143, 2018
52018