Nitric oxide monitoring in brain extracellular fluid: characterisation of Nafion®-modified Pt electrodes in vitro and in vivo FO Brown, NJ Finnerty, JP Lowry Analyst 134 (10), 2012-2020, 2009 | 60 | 2009 |
Calibration of NO sensors for in-vivo voltammetry: laboratory synthesis of NO and the use of UV–visible spectroscopy for determining stock concentrations FO Brown, NJ Finnerty, FB Bolger, J Millar, JP Lowry Analytical and bioanalytical chemistry 381, 964-971, 2005 | 52 | 2005 |
Prefrontal GABAB receptor activation attenuates phencyclidine-induced impairments of prepulse inhibition: involvement of nitric oxide K Fejgin, E Pålsson, C Wass, N Finnerty, J Lowry, D Klamer Neuropsychopharmacology 34 (7), 1673-1684, 2009 | 38 | 2009 |
Brain nitric oxide: Regional characterisation of a real-time microelectrochemical sensor NJ Finnerty, SL O’Riordan, E Palsson, JP Lowry Journal of neuroscience methods 209 (1), 13-21, 2012 | 35 | 2012 |
An investigation of hypofrontality in an animal model of schizophrenia using real-time microelectrochemical sensors for glucose, oxygen, and nitric oxide NJ Finnerty, FB Bolger, E Pålsson, JP Lowry ACS Chemical Neuroscience 4 (5), 825-831, 2013 | 30 | 2013 |
In vivo characterisation of a Nafion®-modified Pt electrode for real-time nitric oxide monitoring in brain extracellular fluid NJ Finnerty, SL O'Riordan, FO Brown, PA Serra, RD O'Neill, JP Lowry Analytical methods 4 (2), 550-557, 2012 | 29 | 2012 |
Increased brain nitric oxide levels following ethanol administration N Finnerty, SL O'Riordan, D Klamer, J Lowry, E Pålsson Nitric Oxide 47, 52-57, 2015 | 28 | 2015 |
Increased cortical nitric oxide release after phencyclidine administration E Pålsson, N Finnerty, K Fejgin, D Klamer, C Wass, L Svensson, J Lowry Synapse 63 (12), 1083-1088, 2009 | 28 | 2009 |
In vitro characterisation of ortho phenylenediamine and NafionŪ-modified Pt electrodes for measuring brain nitric oxide AM Wynne, CH Reid, NJ Finnerty Journal of Electroanalytical Chemistry 732, 110-116, 2014 | 24 | 2014 |
Continuous real-time in vivo measurement of cerebral nitric oxide supports theoretical predictions of an irreversible switching in cerebral ROS after sufficient exposure to … NJ Finnerty, SL O'Riordan, JP Lowry, M Cloutier, P Wellstead Journal of Parkinson's disease 3 (3), 351-362, 2013 | 13 | 2013 |
Physiological monitoring of tissue pH: in vitro characterisation and in vivo validation of a quinone-modified carbon paste electrode KM Herdman, CB Breslin, NJ Finnerty Electrochimica Acta 298, 484-495, 2019 | 10 | 2019 |
In vitro development and in vivo application of a platinum-based electrochemical device for continuous measurements of peripheral tissue oxygen NJ Finnerty, FB Bolger Bioelectrochemistry 119, 124-135, 2018 | 10 | 2018 |
Long term amperometric recordings in the brain extracellular fluid of freely moving immunocompromised NOD SCID mice CH Reid, NJ Finnerty Sensors 17 (2), 419, 2017 | 9 | 2017 |
A platinum oxide-based microvoltammetric pH electrode suitable for physiological investigations NJ Finnerty, FB Bolger Analyst 143 (13), 3124-3133, 2018 | 8 | 2018 |
In–Vitro Development and Characterisation of a Superoxide Dismutase‐Based Biosensor. MM Doran, NJ Finnerty, JP Lowry ChemistrySelect 2 (14), 4157-4164, 2017 | 8 | 2017 |
Electrochemical sensors: in-vitro and in-vivo analysis of brain nitric oxide and regional cerebral blood flow NJ Finnerty National University of Ireland, Maynooth, 2008 | 7 | 2008 |
An electrochemical investigation into the effects of local and systemic administrations of sodium nitroprusside in brain extracellular fluid of mice CH Reid, NJ Finnerty Bioelectrochemistry 132, 107441, 2020 | 6 | 2020 |
Real-Time Amperometric Recording of Extracellular H2O2 in the Brain of Immunocompromised Mice: An In Vitro, Ex Vivo and In Vivo Characterisation Study CH Reid, NJ Finnerty Sensors 17 (7), 1596, 2017 | 6 | 2017 |
Ascorbic acid rejection characteristics of modified platinum electrodes: a shelf life investigation AM Wynne, NJ Finnerty Chemosensors 3 (2), 55-69, 2015 | 6 | 2015 |
The aqueous deposition of a pH sensitive quinone on carbon paste electrodes using linear sweep voltammetry KM Herdman, CB Breslin, NJ Finnerty Journal of Electroanalytical Chemistry 828, 137-143, 2018 | 5 | 2018 |