Follow
Estellito Rangel Junior
Estellito Rangel Junior
Consultor, Ex-periência & Soluções
Verified email at crea-rj.org.br
Title
Cited by
Cited by
Year
Maintenance Strategy for Electrical Equipment Based on Integrated Operations
ARS Queiroz, EC Senger, LCL Queiroz, E Rangel, VS de Paula
IEEE Transactions on Industry Applications 53 (3), 3189-3197, 2016
112016
The importance of inspections on electrical installations in hazardous locations
E Rangel, ARS Queiroz, MF de Oliveira
2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC), 155-161, 2014
102014
International standards on explosive atmospheres: harmonization is a hard but necessary task
E Rangel, CA Sanguedo
Petroleum and Chemical Industry Conference Europe Electrical and …, 2011
102011
Brazil moves from divisions to zones [hazardous location safety]
E Rangel
Record of Conference Papers. Industry Applications Society. Forty-Ninth …, 2002
92002
A comparative study between copper and aluminum induction squirrel cage constructions
R Yabiku, R Fialho, L Teran, A Santos, E Rangel, D Dutra
2010 Record of Conference Papers Industry Applications Society 57th Annual …, 2010
82010
Classification of hazardous areas: Standard, theory and practice
E Rangel Jr
Ex Magazine, 15-21, 2010
72010
Explosion Risk in Underground Networks: Measures for Preventing Manhole Explosion Events
E Rangel
IEEE Industry Applications Magazine 20 (5), 58-63, 2014
62014
Area Classification Is Not a Copy-and-Paste Process: Performing Reliable Hazardous-Area-Classification Studies
E Rangel, AM Luiz, HL de PM Filho
IEEE Industry Applications Magazine 22 (1), 28-39, 2015
52015
New requirements for electrical installations in hazardous locations
E Rangel, CA Sanguedo
2017 Petroleum and Chemical Industry Technical Conference (PCIC), 443-450, 2017
42017
Safety in electrical installations in petroleum industry
E Rangel Jr
1st IEEE PCIC Mexico Conference Record, 2013
42013
Safety at work in hazardous (classified) locations
E Rangel, B Roberval
LII Petroleum and Chemical Industry Conference, 17-23, 2005
42005
Explosões urbanas: risco anunciado
E Rangel Jr
VII Encontro Nacional de Segurança, Saúde e Meio Ambiente, Salvador, Anais …, 2000
42000
Explosões nas indústrias químicas–Prevenção pró-ativa
E RANGEL Jr
VI ENCONTRO NACIONAL DE SEGURANÇA, SAÚDE E MEIO-AMBIENTE, 153-161, 1999
41999
Differences and Similarities Between ANSI and IEC Cultures for MV Assemblies—The Brazilian Experience
LF de Oliveira Costa, E Rangel, JM de Carvalho Filho, RC Barros
IEEE Transactions on Industry Applications 50 (4), 2392-2402, 2013
32013
The importance of inspections in classified areas
E Rangel Jr
Vector Mag. 11 (115), 52-54, 2005
32005
Considerations on the New Requirements for Electrical Installations in Hazardous Locations
E Rangel, CA Sanguedo
IEEE Transactions on Industry Applications 55 (1), 1030-1036, 2018
22018
Area classification is not a copy and paste process
E Rangel, AM Luiz, HL de PM Filho
2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC), 381-388, 2014
22014
How to get an adequate electrical installation - part II: Contracts
E Rangel Jr, R Bueno
VIII Petrobras Electrical Engineering Seminar, CD-ROM, Conference Record, 2005
2*2005
Handling changes from Divisions to Zones
E Rangel
IEEE Industry Applications Magazine 10 (3), 49-56, 2004
22004
Inspeção planejada: minimizando os riscos de explosão nas indústrias e sua aplicação para a otimização dos investimentos e dos seguros
E RANGEL Jr
II ENCONTRO NACIONAL SOBRE PREVENÇÃO DE EXPLOSÕES, CD-ROM, 2003
22003
The system can't perform the operation now. Try again later.