Seguir
Arjan Bel
Arjan Bel
Professor Physics Radiotherapy
E-mail confirmado em amc.uva.nl
Título
Citado por
Citado por
Ano
The alfa and beta of tumours: a review of parameters of the linear-quadratic model, derived from clinical radiotherapy studies
CM Van Leeuwen, AL Oei, J Crezee, A Bel, NAP Franken, LJA Stalpers, ...
Radiation oncology 13, 1-11, 2018
4532018
Definition of gross tumor volume in lung cancer: inter-observer variability
J Van de Steene, N Linthout, J De Mey, V Vinh-Hung, C Claassens, ...
Radiotherapy and oncology 62 (1), 37-49, 2002
3312002
A verification procedure to improve patient set-up accuracy using portal images
A Bel, M Van Herk, H Bartelink, JV Lebesque
Radiotherapy and Oncology 29 (2), 253-260, 1993
3111993
High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging
A Bel, PH Vos, PTR Rodrigus, CL Creutzberg, AG Visser, JC Stroom, ...
International Journal of Radiation Oncology• Biology• Physics 35 (2), 321-332, 1996
2861996
Target margins for random geometrical treatment uncertainties in conformal radiotherapy
A Bel, M van Herk, JV Lebesque
Medical physics 23 (9), 1537-1545, 1996
1891996
Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation
J Van de Steene, F Van den Heuvel, A Bel, D Verellen, J De Mey, ...
International Journal of Radiation Oncology* Biology* Physics 40 (4), 967-976, 1998
1601998
Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region
D Verellen, N Linthout, D Van Den Berge, A Bel, G Storme
International Journal of Radiation Oncology* Biology* Physics 39 (1), 99-114, 1997
1551997
Time trend of patient setup deviations during pelvic irradiation using electronic portal imaging
AAH El-Gayed, A Bel, R Vijlbrief, H Bartelink, JV Lebesque
Radiotherapy and Oncology 26 (2), 162-171, 1993
1511993
Adequate margins for random setup uncertainties in head-and-neck IMRT
E Astreinidou, A Bel, CPJ Raaijmakers, CHJ Terhaard, JJW Lagendijk
International Journal of Radiation Oncology* Biology* Physics 61 (3), 938-944, 2005
1462005
Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device
A Bel, R Keus, RE Vijlbrief, JV Lebesque
Radiotherapy and Oncology 37 (2), 153-159, 1995
1131995
Improving locoregional hyperthermia delivery using the 3-D controlled AMC-8 phased array hyperthermia system: A preclinical study
J Crezee, PMA Van Haaren, H Westendorp, M De Greef, HP Kok, ...
International journal of hyperthermia 25 (7), 581-592, 2009
1082009
Interfractional position variation of pancreatic tumors quantified using intratumoral fiducial markers and daily cone beam computed tomography
A Van Der Horst, S Wognum, RD Fajardo, R De Jong, JE Van Hooft, ...
International Journal of Radiation Oncology* Biology* Physics 87 (1), 202-208, 2013
922013
Accelerated ray tracing for radiotherapy dose calculations on a GPU
M De Greef, J Crezee, JC Van Eijk, R Pool, A Bel
Medical physics 36 (9Part1), 4095-4102, 2009
862009
Optimization in hyperthermia treatment planning: the impact of tissue perfusion uncertainty
M De Greef, HP Kok, D Correia, A Bel, J Crezee
Medical physics 37 (9), 4540-4550, 2010
842010
Quantifying the combined effect of radiation therapy and hyperthermia in terms of equivalent dose distributions
HP Kok, J Crezee, NAP Franken, LJA Stalpers, GW Barendsen, A Bel
International Journal of Radiation Oncology* Biology* Physics 88 (3), 739-745, 2014
812014
Uncertainty in hyperthermia treatment planning: the need for robust system design
M De Greef, HP Kok, D Correia, PP Borsboom, A Bel, J Crezee
Physics in Medicine & Biology 56 (11), 3233, 2011
762011
Influence of daily setup measurements and corrections on the estimated delivered dose during IMRT treatment of prostate cancer patients
PMA van Haaren, A Bel, P Hofman, M van Vulpen, ANTJ Kotte, ...
Radiotherapy and oncology 90 (3), 291-298, 2009
752009
Differences in respiratory-induced pancreatic tumor motion between 4D treatment planning CT and daily cone beam CT, measured using intratumoral fiducials
E Lens, A van der Horst, PS Kroon, JE van Hooft, R Dávila Fajardo, ...
Acta Oncologica 53 (9), 1257-1264, 2014
722014
A short time interval between radiotherapy and hyperthermia reduces in-field recurrence and mortality in women with advanced cervical cancer
CM van Leeuwen, AL Oei, KWTK Chin, J Crezee, A Bel, AM Westermann, ...
Radiation Oncology 12, 1-8, 2017
702017
Behavior of lipiodol markers during image guided radiotherapy of bladder cancer
X Chai, M van Herk, JB van de Kamer, P Remeijer, A Bex, A Betgen, ...
International Journal of Radiation Oncology* Biology* Physics 77 (1), 309-314, 2010
702010
O sistema não pode executar a operação agora. Tente novamente mais tarde.
Artigos 1–20