Two‐dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device SC Vieira, RSJP Kaatee, MLP Dirkx, BJM Heijmen Medical physics 30 (11), 2981-2987, 2003 | 85 | 2003 |
Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device SC Vieira, MLP Dirkx, KL Pasma, BJM Heijmen Medical physics 29 (9), 2034-2040, 2002 | 81 | 2002 |
Safety and efficacy of virtual prostatectomy with single-dose radiotherapy in patients with intermediate-risk prostate cancer: results from the PROSINT phase 2 randomized … C Greco, O Pares, N Pimentel, V Louro, I Santiago, S Vieira, J Stroom, ... JAMA oncology 7 (5), 700-708, 2021 | 48 | 2021 |
Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device SC Vieira, MLP Dirkx, KL Pasma, BJM Heijmen Physics in Medicine & Biology 48 (2), 157, 2002 | 48 | 2002 |
Developments in zebrafish avatars as radiotherapy sensitivity reporters—towards personalized medicine B Costa, S Ferreira, V Póvoa, MJ Cardoso, S Vieira, J Stroom, P Fidalgo, ... EBioMedicine 51, 2020 | 42 | 2020 |
SIFT: a method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device SC Vieira, MLP Dirkx, BJM Heijmen, HCJ de Boer International Journal of Radiation Oncology* Biology* Physics 60 (3), 981-993, 2004 | 42 | 2004 |
Fast, daily linac verification for segmented IMRT using electronic portal imaging SC Vieira, RA Bolt, MLP Dirkx, AG Visser, BJM Heijmen Radiotherapy and oncology 80 (1), 86-92, 2006 | 39 | 2006 |
Portal dose image prediction for dosimetric treatment verification in radiotherapy. II. An algorithm for wedged beams KL Pasma, SC Vieira, BJM Heijmen Medical Physics 29 (6), 925-931, 2002 | 36 | 2002 |
Combined recipe for clinical target volume and planning target volume margins J Stroom, K Gilhuijs, S Vieira, W Chen, J Salguero, E Moser, JJ Sonke International Journal of Radiation Oncology* Biology* Physics 88 (3), 708-714, 2014 | 31 | 2014 |
On the robustness of VMAT-SABR treatment plans against isocentre positioning uncertainties J Stroom, S Vieira, D Mateus, C Greco, A Fogliata, G Nicolini, A Clivio, ... Radiation Oncology 9, 1-9, 2014 | 16 | 2014 |
Calypso® 4D localization system: a review C Silva, D Mateus, M Eiras, S Vieira Journal of Radiotherapy in Practice 13 (4), 473-483, 2014 | 13 | 2014 |
Treatment planning with intensity modulated particle therapy for multiple targets in stage IV non-small cell lung cancer K Anderle, J Stroom, S Vieira, N Pimentel, C Greco, M Durante, C Graeff Physics in Medicine & Biology 63 (2), 025034, 2018 | 9 | 2018 |
Reproducibility and accuracy of a target motion mitigation technique for dose-escalated prostate stereotactic body radiotherapy C Greco, J Stroom, S Vieira, D Mateus, MJ Cardoso, A Soares, O Pares, ... Radiotherapy and Oncology 160, 240-249, 2021 | 8 | 2021 |
Organ dose measurements using an adult anthropomorphic phantom and risk estimation of cancer incidence from CBCT exposures M Baptista, S Di Maria, S Vieira, J Pereira, M Pereira, P Vaz Radiation Physics and Chemistry 171, 108715, 2020 | 8 | 2020 |
IMRT national audit in Portugal T Santos, M do Carmo Lopes, E Gershkevitsh, F Vinagre, D Faria, L Carita, ... Physica Medica 65, 128-136, 2019 | 7 | 2019 |
Dosimetric verification of intensity modulated radiotherapy with an electronic portal imaging device S Vieira | 7 | 2005 |
Urethra sparing with target motion mitigation in dose-escalated extreme hypofractionated prostate cancer radiotherapy: 7-year results from a phase II study C Greco, O Pares, N Pimentel, V Louro, B Nunes, J Kociolek, J Stroom, ... Frontiers in Oncology 12, 863655, 2022 | 3 | 2022 |
Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures M Baptista, S Di Maria, S Vieira, J Santos, J Pereira, M Pereira, P Vaz Radiation and Environmental Biophysics 58, 21-37, 2019 | 3 | 2019 |
Process managment and Quality Assurance of Intracranial Stereotactic Treatment S Heukelom, J Hermans, N Hoffmans-Holtzer, H Marijnissen, A Nulens, ... Process managment and Quality Assurance of Intracranial Stereotactic …, 2015 | 3 | 2015 |
PO-1027 IMRT in breath hold for left breast cancer patients: surface tracking and clinical implementation M Cardoso, S Vieira, A Martins, A Soares, M Possanzini, J Morales, ... Radiotherapy and Oncology 133, S569-S570, 2019 | 2 | 2019 |