Seguir
Matthieu Labat
Matthieu Labat
maître de conférences, INSA Toulouse
E-mail confirmado em insa-toulouse.fr
Título
Citado por
Citado por
Ano
From the experimental characterization of the hygrothermal properties of straw-clay mixtures to the numerical assessment of their buffering potential
M Labat, C Magniont, N Oudhof, JE Aubert
Building and Environment 97, 69-81, 2016
1462016
The impact of latent heat exchanges on the design of earth air heat exchangers
E Estrada, M Labat, S Lorente, LAO Rocha
Applied Thermal Engineering 129, 306-317, 2018
722018
Dynamic coupling between vapour and heat transfer in wall assemblies: Analysis of measurements achieved under real climate
M Labat, M Woloszyn, G Garnier, JJ Roux
Building and Environment 87, 129-141, 2015
632015
Role of flow architectures on the design of radiant cooling panels, a constructal approach
M Mosa, M Labat, S Lorente
Applied Thermal Engineering 150, 1345-1352, 2019
572019
Comparison of the Saturated Salt Solution and the Dynamic Vapor Sorption techniques based on the measured sorption isotherm of barley straw
R Bui, M Labat, JE Aubert
Construction and Building Materials 141, 140-151, 2017
552017
Experimental assessment of a PCM to air heat exchanger storage system for building ventilation application
M Labat, J Virgone, D David, F Kuznik
Applied thermal engineering 66 (1-2), 375-382, 2014
552014
Assessment of the air change rate of airtight buildings under natural conditions using the tracer gas technique. Comparison with numerical modelling
M Labat, M Woloszyn, G Garnier, JJ Roux
Building and environment 60, 37-44, 2013
512013
Constructal design of flow channels for radiant cooling panels
M Mosa, M Labat, S Lorente
International Journal of Thermal Sciences 145, 106052, 2019
402019
Impact of direct solar irradiance on heat transfer behind an open-jointed ventilated cladding: Experimental and numerical investigations
M Labat, M Woloszyn, G Garnier, G Rusaouen, JJ Roux
Solar Energy 86 (9), 2549-2560, 2012
362012
Numerical estimation and sensitivity analysis of the energy demand for six industrial buildings in France
M Labat, K Attonaty
Journal of Building Performance Simulation 11 (2), 223-240, 2018
202018
Influence of the arrangement of multiple radiant ceiling panels on the radiant temperature field
M Labat, S Lorente, M Mosa
International Journal of Thermal Sciences 149, 106184, 2020
192020
Laboratory test to assess sensitivity of bio-based earth materials to fungal growth
A Laborel-Préneron, K Ouédraogo, A Simons, M Labat, A Bertron, ...
Building and Environment 142, 11-21, 2018
192018
Moisture balance assessment at room scale for four cases based on numerical simulations of heat–air–moisture transfers for a realistic occupancy scenario
M Labat, M Woloszyn
Journal of Building Performance Simulation 9 (5), 487-509, 2016
182016
Impact of the occupancy scenario on the hygrothermal performance of a room
R Bui, M Labat, S Lorente
Building and Environment 160, 106178, 2019
152019
Chaleur–Humidité–Air dans les maisons à ossature bois: Expérimentation et modélisation
M Labat
Lyon, INSA, 2012
152012
Chaleur–Humidité–Air dans les maisons à ossature bois: Expérimentation et modélisation
M Labat
Lyon, INSA, 2012
152012
Numerical‐analytical study of earth‐air heat exchangers with complex geometries guided by constructal design
BR Nunes, MK Rodrigues, LA Oliveira Rocha, M Labat, S Lorente, ...
International Journal of Energy Research 45 (15), 20970-20987, 2021
142021
Simulating combined heat and moisture transfer with energyplus: an uncertainty study and comparison with experimental data
C Spitz, M Woloszyn, C Buhé, M Labat
142013
Measurement of the hygrothermal properties of straw-clay mixtures
N Oudhof, M Labat, C Magniont, P Nicot
Academic Journal of Civil Engineering 33 (2), 474-479, 2015
92015
Improving the performances of earth air heat exchangers through Constructal design
R da Silva Brum, M Labat, S Lorente
International Journal of Energy Research 43 (14), 8822-8833, 2019
82019
O sistema não pode executar a operação agora. Tente novamente mais tarde.
Artigos 1–20