Follow
Arijit Baral
Arijit Baral
IIT(ISM) Dhanbad
Verified email at iitism.ac.in
Title
Cited by
Cited by
Year
Assessment of interfacial charge accumulation in oil-paper interface in transformer insulation from polarization-depolarization current measurements
D Mishra, N Haque, A Baral, S Chakravorti
IEEE Transactions on dielectrics and electrical insulation 24 (3), 1665-1673, 2017
632017
Condition assessment of cellulosic part in power transformer insulation using transfer function zero of modified Debye model
A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 21 (5), 2028-2036, 2014
602014
An expert system approach for transformer insulation diagnosis combining conventional diagnostic tests and PDC, RVM data
S Sarkar, T Sharma, A Baral, B Chatterjee, D Dey, S Chakravorti
IEEE transactions on Dielectrics and Electrical Insulation 21 (2), 882-891, 2014
582014
A modified Maxwell model for characterization of relaxation processes within insulation system having non-uniform aging due to temperature gradient
A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 20 (2), 524-534, 2013
532013
Assessment of non-uniform aging of solid dielectric using system poles of a modified debye model for oil-paper insulation of transformers
A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 20 (5), 1922-1933, 2013
462013
Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified Debye model
A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 21 (3), 1368-1375, 2014
432014
Condition assessment of power transformer insulation using short-duration time-domain dielectric spectroscopy measurement data
D Mishra, A Baral, N Haque, S Chakravorti
IEEE Transactions on Instrumentation and Measurement 69 (7), 4404-4411, 2019
362019
Effect of measurement temperature on power transformer insulation diagnosis using frequency‐domain spectroscopy
S Dutta, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 11 (6), 773-779, 2017
332017
A method to estimate activation energy of power transformer insulation using time domain spectroscopy data
HC Verma, A Baral, AK Pradhan, S Chakravorti
IEEE transactions on Dielectrics and Electrical Insulation 24 (5), 3245-3253, 2017
282017
A new approach for determination of moisture in paper insulation of in-situ power transformers by combining polarization-depolarization current and return voltage measurement …
S Sarkar, T Sharma, A Baral, B Chatterjee, D Dey, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 20 (6), 2325-2334, 2013
282013
Effect of charge accumulated at oil–paper interface on parameters considered for power transformer insulation diagnosis
D Mishra, N Haque, A Baral, S Chakravorti
IET Science, Measurement & Technology 12 (3), 411-417, 2018
252018
Use of interfacial charge for diagnosis and activation energy prediction of oil-paper insulation used in power transformer
D Mishra, S Dutta, A Baral, N Haque, S Chakravorti
IEEE Transactions on Power Delivery 34 (4), 1332-1340, 2019
202019
Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer
D Mishra, AK Pradhan, A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 25 (5), 1932-1940, 2018
192018
Compensating the effect of temperature variation on dielectric response of oil-paper insulation used in power transformers
A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 23 (4), 2462-2474, 2016
192016
Application of framelet transform in filtering baseline drift from ECG signals
A Sanyal, A Baral, A Lahiri
Procedia Technology 4, 862-866, 2012
182012
An ant colony system based control of shunt capacitor banks for bulk electricity consumers
P Sarkar, A Baral, K Das, P Syam
Applied Soft Computing 43, 520-534, 2016
162016
Estimation of paper‐moisture in transformer insulation employing dielectric spectroscopy data
A Kumar, HC Verma, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 12 (4), 536-541, 2018
152018
Estimation of de‐trapped charge for diagnosis of transformer insulation using short‐duration polarisation current employing detrended fluctuation analysis
S Dutta, D Mishra, A Baral, S Chakravorti
High Voltage 5 (5), 636-641, 2020
132020
Detrapped charge-affected depolarization-current estimation using short-duration dielectric response for diagnosis of transformer insulation
CM Banerjee, A Baral, S Chakravorti
IEEE Transactions on Instrumentation and Measurement 69 (10), 7695-7702, 2020
132020
Condition assessment of various regions within non‐uniformly aged cellulosic insulation of power transformer using modified Debye model
HC Verma, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 11 (7), 939-947, 2017
132017
The system can't perform the operation now. Try again later.
Articles 1–20