Study of the laboratory Vane test on mortars E Bauer, JGG de Sousa, EA Guimarães, FGS Silva Building and environment 42 (1), 86-92, 2007 | 82 | 2007 |
Analysis of building facade defects using infrared thermography: Laboratory studies E Bauer, E Pavón, E Barreira, EK De Castro Journal of Building Engineering 6, 93-104, 2016 | 79 | 2016 |
Infrared thermography–evaluation of the results reproducibility E Bauer, VP de Freitas, N Mustelier, E Barreira, SS de Freitas Structural survey 33 (1), 20-35, 2015 | 70 | 2015 |
Revestimentos de argamassa: características e peculiaridades E BAUER Brasília: LEM-UnB, 2005 | 66 | 2005 |
Evaluating the damage degree of cracking in facades using infrared thermography E Bauer, PM Milhomem, LAG Aidar Journal of Civil Structural Health Monitoring 8 (3), 517-528, 2018 | 53 | 2018 |
Estimativa da degradação de fachadas com revestimento cerâmico: estudo de caso de edifícios de Brasília E Bauer, EK Castro, MNB Silva Cerâmica 61, 151-159, 2015 | 48* | 2015 |
Avaliação comparativa da influência da adição de escória de alto-forno na corrosão das armaduras através de técnicas eletroquímicas E Bauer, PRL Helene | 37 | 1995 |
Termografia de infravermelho na identificação e avaliação de manifestações patológicas em edifícios E Bauer, E Pavón Revista Concreto e Construções 79 (1), 93-98, 2015 | 36 | 2015 |
Wind-driven rain incidence parameters obtained by hygrothermal simulation MLM Nascimento, E Bauer, JS De Souza, VAG Zanoni Journal of Building Pathology and Rehabilitation 1, 1-7, 2016 | 33 | 2016 |
Analysis of the influencing factors of external wall ceramic claddings' service life using regression techniques J Souza, A Silva, J de Brito, E Bauer Engineering Failure Analysis 83, 141-155, 2018 | 32 | 2018 |
Relative importance of pathologies in the severity of facade degradation E Bauer, CB Piazzarollo, JS de Souza, DG dos Santos Journal of Building Pathology and Rehabilitation 5 (1), 7, 2020 | 28 | 2020 |
Study of damage distribution and intensity in regions of the facade JS de Souza, E Bauer, MLM Nascimento, VMS Capuzzo, VAG Zanoni Journal of Building Pathology and Rehabilitation 1, 1-9, 2016 | 28 | 2016 |
Facades inspection with infrared thermography: cracks evaluation E Bauer, E Pavón, E Oliveira, CHF Pereira Journal of Building Pathology and Rehabilitation 1, 1-7, 2016 | 28 | 2016 |
Identification and quantification of failure modes of new buildings façades in Brasília E Bauer, EK Castro, FE Leal, GR Antunes Proceedings of XII International Conference on Durability of Building …, 2011 | 28 | 2011 |
Evaluation of damage of building facades in Brasília E Bauer, E Kraus, MNB Silva, VAG Zanoni XIII DBMC-International Conference on Durability of Building Materials and …, 2014 | 27 | 2014 |
Service life prediction of ceramic tiling systems in Brasília-Brazil using the factor method J Souza, A Silva, J de Brito, E Bauer Construction and building materials 192, 38-49, 2018 | 26 | 2018 |
Requisitos das argamassas estabilizadas para revestimento E BAUER, M REGUFFE, MLM NASCIMENTO, LR CALDAS Simpósio Brasileiro de Tecnologia das Argamassas 11, 2015 | 24 | 2015 |
Degradação de fachadas revestidas em argamassas nos edifícios de Brasília, Brasil E Bauer, JS Souza, LMG Mota Ambiente Construído 21, 23-43, 2021 | 22 | 2021 |
Criteria for identification of ceramic detachments in building facades with infrared thermography E Bauer, E Pavón, CHF Pereira, MLM Nascimento Recent developments in building diagnosis techniques, 51-68, 2016 | 21 | 2016 |
Resistência a penetração da chuva em fachadas de alvenaria de materiais cerâmicos: uma análise de desempenho E Bauer | 21 | 1987 |